Datasheet Texas Instruments SN65HVD12PE4 — Ficha de datos
Fabricante | Texas Instruments |
Serie | SN65HVD12 |
Numero de parte | SN65HVD12PE4 |
Transceptor diferencial de 3.3V 8-PDIP -40 a 85
Hojas de datos
SNx5HVD1x 3.3-V RS-485 Transceivers datasheet
PDF, 1.2 Mb, Revisión: O, Archivo publicado: feb 1, 2017
Extracto del documento
Precios
Estado
Estado del ciclo de vida | Activo (Recomendado para nuevos diseños) |
Disponibilidad de muestra del fabricante | Sí |
Embalaje
Pin | 8 |
Package Type | P |
Industry STD Term | PDIP |
JEDEC Code | R-PDIP-T |
Package QTY | 50 |
Carrier | TUBE |
Device Marking | 65HVD12 |
Width (mm) | 6.35 |
Length (mm) | 9.81 |
Thickness (mm) | 3.9 |
Pitch (mm) | 2.54 |
Max Height (mm) | 5.08 |
Mechanical Data | Descargar |
Paramétricos
Common Mode Range | -7 to 12 |
Duplex | Half |
Fail Safe | Idle,Open,Short |
Fault Protection | -9 to 14 V |
HBM ESD | 16 kV |
ICC(Max) | 15.5 mA |
IEC 61000-4-2 Contact | N/A +/- kV |
Isolated | No |
No. of RX | 1 |
No. of TX | 1 |
Number of Nodes | 256 |
Operating Temperature Range | -40 to 85 C |
Package Group | PDIP |
Rating | Catalog |
Signaling Rate(Max) | 1 Mbps |
Supply Voltage(s)(Nom) | 3.3 V |
Plan ecológico
RoHS | Obediente |
Pb gratis | Sí |
Kits de diseño y Módulos de evaluación
- Evaluation Modules & Boards: RS485-HF-DPLX-EVM
RS-485 Half-Duplex Evaluation Module
Estado del ciclo de vida: Activo (Recomendado para nuevos diseños)
Notas de aplicación
- RS-485 failsafe biasing: Old versus new transceiversPDF, 131 Kb, Archivo publicado: abr 16, 2013
- RS-485 for E-Meter Applications (Rev. A)PDF, 311 Kb, Revisión: A, Archivo publicado: agosto 6, 2004
This application report discusses the best practices for designing energy meter communication circuits using the RS-485 standard. Component selection and performance tradeoffs are covered with reference to relevant standards such as IEC 61036 and DL/T 645. Reference design details are provided to help energy meter engineers successfully complete their own circuit designs. - 2Q 2013 Issue Analog Applications JournalPDF, 2.5 Mb, Archivo publicado: abr 16, 2013
- The RS-485 Unit Load and Maximum Number of Bus ConnectionsPDF, 197 Kb, Archivo publicado: marzo 15, 2004
The TIA/EIA-485 (RS-485) standard defines a Unit Load and confines bus configurations to 32. This report explains the Unit-Load concept and how it relates to the maximum number of bus connections. Fractional Unit-Load devices, such at the 1/8th Unit-Load SN65HVD21 and SN65HVD06, allow up to 256 devices on a single bus segment.
Linea modelo
Serie: SN65HVD12 (6)
- SN65HVD12D SN65HVD12DG4 SN65HVD12DR SN65HVD12DRG4 SN65HVD12P SN65HVD12PE4
Clasificación del fabricante
- Semiconductors > Interface > RS-485/RS-422