Datasheet Texas Instruments LMV981MGX/NOPB — Ficha de datos

FabricanteTexas Instruments
SerieLMV981-N
Numero de parteLMV981MGX/NOPB
Datasheet Texas Instruments LMV981MGX/NOPB

Amplificadores operacionales individuales de 1.8V, RRIO con apagado 6-SC70 -40 a 125

Hojas de datos

LMV98x-N Small, Low-Power, 1.8-V RRIO Operational Amplifiers With Shutdown datasheet
PDF, 1.6 Mb, Revisión: M, Archivo publicado: sept 30, 2016
Extracto del documento

Precios

Estado

Estado del ciclo de vidaActivo (Recomendado para nuevos diseños)
Disponibilidad de muestra del fabricanteNo

Embalaje

Pin6
Package TypeDCK
Industry STD TermSOT-SC70
JEDEC CodeR-PDSO-G
Package QTY3000
CarrierLARGE T&R
Device MarkingA77
Width (mm)1.25
Length (mm)2
Thickness (mm).9
Pitch (mm).65
Max Height (mm)1.1
Mechanical DataDescargar

Paramétricos

Additional FeaturesShutdown
ArchitectureBipolar
CMRR(Min)60 dB
CMRR(Typ)86 dB
GBW(Typ)1.5 MHz
Input Bias Current(Max)35000 pA
Iq per channel(Max)0.23 mA
Iq per channel(Typ)0.116 mA
Number of Channels1
Offset Drift(Typ)5.5 uV/C
Operating Temperature Range-40 to 125 C
Output Current(Typ)65 mA
Package GroupSC70
Package Size: mm2:W x L6SC70: 4 mm2: 2.1 x 2(SC70) PKG
Rail-to-RailIn,Out
RatingCatalog
Slew Rate(Typ)0.42 V/us
Total Supply Voltage(Max)5 +5V=5, +/-5V=10
Total Supply Voltage(Min)1.8 +5V=5, +/-5V=10
Vn at 1kHz(Typ)50 nV/rtHz
Vos (Offset Voltage @ 25C)(Max)4 mV

Plan ecológico

RoHSObediente

Notas de aplicación

  • AN-1515 A Comprehensive Study of the Howland Current Pump (Rev. A)
    PDF, 165 Kb, Revisión: A, Archivo publicado: abr 26, 2013
    It is well known to analog experts that you can use the positive and negative inputs of an operationalamplifier to make a high-impedance current source (current pump) using a conventional operationalamplifier (op amp). This basic circuit can put out both + and - output current (or zero current) into variousloads. The theory is simple. But the practical problems involved are not so simple or
  • AN-1684 Saving Power in an AC-Coupled Amplifier Circuit (Rev. A)
    PDF, 99 Kb, Revisión: A, Archivo publicado: abr 26, 2013
    AC-coupled circuits are often used for single supply operation to bring the input voltage into the inputrange of the amplifier. This circuit topology can be used in AC smoke detectors or in AC proximitysensors.

Linea modelo

Clasificación del fabricante

  • Semiconductors > Amplifiers > Operational Amplifiers (Op Amps) > General-Purpose Op Amps