Datasheet Texas Instruments HPA00630IPWR — Ficha de datos

FabricanteTexas Instruments
SerieADS1230
Numero de parteHPA00630IPWR
Datasheet Texas Instruments HPA00630IPWR

ADC Delta Sigma de 20 bits para sensores de puente 16-TSSOP -40 a 85

Hojas de datos

20-Bit Analog-to-Digital Converter for Bridge Sensors datasheet
PDF, 1.1 Mb, Revisión: B, Archivo publicado: sept 5, 2012
Extracto del documento

Precios

Estado

Estado del ciclo de vidaActivo (Recomendado para nuevos diseños)
Disponibilidad de muestra del fabricanteNo

Embalaje

Pin16
Package TypePW
Industry STD TermTSSOP
JEDEC CodeR-PDSO-G
Package QTY2000
CarrierLARGE T&R
Device MarkingADS1230
Width (mm)4.4
Length (mm)5
Thickness (mm)1
Pitch (mm).65
Max Height (mm)1.2
Mechanical DataDescargar

Paramétricos

# Input Channels1
Analog Voltage AVDD(Max)5.3 V
Analog Voltage AVDD(Min)2.7 V
ArchitectureDelta-Sigma
Digital Supply(Max)5.3 V
Digital Supply(Min)2.7 V
INL(Max)6.29 +/-LSB
Input Range(Max)0.039 V
Input TypeDifferential,Single-Ended
Integrated Features50/60 Hz Rejection,Oscillator,PGA
InterfaceSPI
Multi-Channel ConfigurationN/A
Operating Temperature Range-40 to 85 C
Package GroupTSSOP
Package Size: mm2:W x L16TSSOP: 32 mm2: 6.4 x 5(TSSOP) PKG
Power Consumption(Typ)2.9 mW
RatingCatalog
Reference ModeExt
Resolution20 Bits
Sample Rate (max)80SPS SPS
Sample Rate(Max)0.00008 MSPS

Plan ecológico

RoHSObediente

Notas de aplicación

  • Delta-Sigma ADC Design for Bridge Sensor Applications
    PDF, 98 Kb, Archivo publicado: sept 30, 2011
    This application report reviews several different types of bridge sensors, including characteristics of each type, and discusses the key parameters of delta-sigma (О”ОЈ) analog-to-digital converters (ADCs) at the system level. Additionally, the parameters of a О”ОЈ ADC are considered for use in common bridge sensor applications
  • Digital Filter Types in Delta-Sigma ADCs
    PDF, 219 Kb, Archivo publicado: jun 27, 2017
    This application report discusses digital filters which are a ubiquitous feature in delta-sigma analog todigital converters (ADCs). Digital low-pass filters are essential to the functionality of a delta-sigma ADCwhich relies on oversampling and noise shaping to push quantization noise out of band. There arevariations between the types of digital filters used in delta-sigma ADCs that provide

Linea modelo

Clasificación del fabricante

  • Semiconductors > Data Converters > Analog-to-Digital Converters (ADCs) > Precision ADCs (<=10MSPS)