Datasheet LTC1051, LTC1053 (Analog Devices)

FabricanteAnalog Devices
DescripciónDual/Quad Precision Zero-Drift Operational Amplifiers with Internal Capacitors
Páginas / Página16 / 1 — FEATURES. DESCRIPTIO. APPLICATIO S. TYPICAL APPLICATIO. High Performance …
Formato / tamaño de archivoPDF / 306 Kb
Idioma del documentoInglés

FEATURES. DESCRIPTIO. APPLICATIO S. TYPICAL APPLICATIO. High Performance Low Cost Instrumentation Amplifier

Datasheet LTC1051, LTC1053 Analog Devices

Línea de modelo para esta hoja de datos

Versión de texto del documento

LTC1051/LTC1053 Dual/Quad Precision Zero-Drift Operational Amplifiers With Internal Capacitors
U FEATURES DESCRIPTIO
■ Dual/Quad Low Cost Precision Op Amp The LTC®1051/LTC1053 are high performance, low cost ■ No External Components Required dual/quad zero-drift operational amplifiers. The unique ■ Maximum Offset Voltage: 5µV achievement of the LTC1051/LTC1053 is that they integrate ■ Maximum Offset Voltage Drift: 0.05µV/°C on chip the sample-and-hold capacitors usually required ■ Low Noise 1.5µV externally by other chopper amplifiers. Further, the P-P (0.1Hz to 10Hz) ■ Minimum Voltage Gain: 120dB LTC1051/LTC1053 offer better combined overall DC and ■ Minimum PSRR: 120dB AC performance than is available from other chopper ■ Minimum CMRR: 114dB stabilized amplifiers with or without internal sample/hold ■ Low Supply Current: 1mA/Op Amp capacitors. ■ Single Supply Operation: 4.75V to 16V The LTC1051/LTC1053 have an offset voltage of 0.5µV, ■ Input Common Mode Range Includes Ground drift of 0.01µV/°C, DC to 10Hz, input noise voltage typically ■ Output Swings to Ground 1.5µVP-P and typical voltage gain of 140dB. The slew rate ■ Typical Overload Recovery Time: 3ms of 4V/µs and gain bandwidth product of 2.5MHz are ■ Pin Compatible with Industry Standard Dual and achieved with only 1mA of supply current per op amp. Quad Op Amps
U
Overload recover times from positive and negative
APPLICATIO S
saturation conditions are 1.5ms and 3ms respectively, about a 100 or more times improvement over chopper ■ Thermocouple Amplifiers amplifiers using external capacitors. ■ Electronic Scales ■ Medical Instrumentation The LTC1051 is available in an 8-lead standard plastic ■ Strain Gauge Amplifiers dual-in-line package as well as a 16-pin SW package. The ■ High Resolution Data Acquisition LTC1053 is available in a standard 14-pin plastic package ■ DC Accurate R C Active Filters and an 18-pin SO. The LTC1051/LTC1053 are plug in replacements for most standard dual/quad op amps with , LTC and LT are registered trademarks of Linear Technology Corporation. improved performance.
U TYPICAL APPLICATIO High Performance Low Cost Instrumentation Amplifier LTC1051 Noise Spectrum
120 R1 R2 Hz) √ 100 5V R2 2 – 8 80 1/2 R1 1 6 LTC1051 – 3 1/2 7 VIN + 60 LTC1051 5 VIN + 4 R1 = 499Ω, 0.1% R2 = 100k, 0.1% 40 – 5V VOLTAGE NOISE DENSITY (nV GAIN = 201 MEASURED CMRR ~ 120dB AT DC MEASURED INPUT VOS 3µV 20 1051/53 TA01a MEASURED INPUT NOISE 2µV 10 100 1k 10k P-P (DC – 10Hz) FREQUENCY (Hz) 1051/53 TA01b 10513fa 1