Datasheet MAX6576, MAX6577 (Maxim) - 2

FabricanteMaxim
DescripciónSOT Temperature Sensors with Period/Frequency Output
Páginas / Página9 / 2 — Absolute Maximum Ratings. Electrical Characteristics. PARAMETER. SYMBOL. …
Formato / tamaño de archivoPDF / 2.0 Mb
Idioma del documentoInglés

Absolute Maximum Ratings. Electrical Characteristics. PARAMETER. SYMBOL. CONDITIONS. MIN. TYP. MAX. UNITS. Note 1:. Note 2:

Absolute Maximum Ratings Electrical Characteristics PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS Note 1: Note 2:

Línea de modelo para esta hoja de datos

Versión de texto del documento

MAX6576/MAX6577 SOT Temperature Sensors with Period/Frequency Output
Absolute Maximum Ratings
Terminal Voltage (with respect to GND) Operating Temperature Range...-40°C to +125°C VDD...-0.3V to +6V Storage Temperature Range..-65°C to +150°C TS1, TS0, OUT...-0.3V to (VDD + 0.3V) Lead Temperature (soldering, 10sec)...+300°C Input/Output Current, All Pins..±20mA Continuous Power Dissipation (TA = +70°C) 6-pin SOT23 (derate 7.10mW/°C above +70°C)..571mW Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
Electrical Characteristics
(VDD = +2.7V to +5.5V, TA = -40°C to +125°C, unless otherwise noted. Typical values are specified at TA = +25°C and VDD = +5V, unless otherwise noted.)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
VDD Range VDD 2.7 5.5 V T Supply Current I A = -40°C to +85°C 140 250 DD VDD = 5.5V µA TA = -40°C to +125°C 400 TA = -20°C -7.5 ±1.1 +7.5 TA = 0°C -5.5 ±0.9 +5.5 MAX6576 TA = +25°C -3.0 ±0.8 +3.0 °C TA = +85°C -4.5 ±0.5 +4.5 Temperature Sensor TA = +125°C -5.0 ±0.5 +5.0 Error (Note 1) TA = -20°C -7.5 ±1.1 +7.5 TA = 0°C -6.5 ±0.9 +6.5 MAX6577 TA = +25°C -3.0 ±0.8 +3.0 °C TA = +85°C -3.5 ±0.5 +3.5 TA = +125°C -4.5 ±0.5 +4.5 VTS1 = GND, VTS0 = GND 10T MAX6576, V Output Clock Period t TS1 = GND, VTS0 = VDD 40T OUT T (temp) in °K, µs Figure 1 VTS1 = VDD, VTS0 = GND 160T VTS1 = VDD, VTS0 = VDD 640T VTS1 = GND, VTS0 = GND 4T MAX6577, V Output Clock Frequency f TS1 = GND, VTS0 = VDD 1T OUT T (temp) in °K, Hz Figure 2 VTS1 = VDD, VTS0 = GND T/4 VTS1 = VDD, VTS0 = VDD T/16 OUT Duty Cycle (Note 2) 0.5 V Time-Select Pin Logic Levels IL 0.8 V VIH 2.3 V V DD > 4.5V, ISINK = 3.2mA 0.4 OL V OUT Voltage DD > 2.7V, ISINK = 1.2mA 0.3 V V V DD > 4.5V, ISRC = 800μA VDD - 1.5 OH VDD > 2.7V, ISRC = 500μA 0.8VDD
Note 1:
See the Temperature Accuracy histograms in the Typical Operating Characteristics.
Note 2:
The output duty cycle is guaranteed to be 50% by an internal flip-flop. www.maximintegrated.com Maxim Integrated │