Datasheet MM5130 (Menlo Micro) - 2

FabricanteMenlo Micro
DescripciónDC to 26 GHz High Power RF Switch
Páginas / Página22 / 2 — v2.0. Electrical Characteristics Operating Characteristics. Table 1. …
Formato / tamaño de archivoPDF / 1.3 Mb
Idioma del documentoInglés

v2.0. Electrical Characteristics Operating Characteristics. Table 1. Parameter. Minimum. Maximum. Unit. CW Input Power @ 6 GHz

v2.0 Electrical Characteristics Operating Characteristics Table 1 Parameter Minimum Maximum Unit CW Input Power @ 6 GHz

Línea de modelo para esta hoja de datos

Versión de texto del documento

2 MM5130 – DC to 26 GHz High Power RF Switch | March 24, 2021
v2.0 Electrical Characteristics Operating Characteristics
Absolute Maximum Ratings

Exceeding the maximum ratings as listed in Table 1 below may reduce the reliability of the device or cause permanent damage. Operation of the MM5130 should be restricted to the limits indicated in Table 2 recommended operating conditions listed below. Electrostatic Discharge (ESD) Safeguards The MM5130 is a Class 0 ESD device. When handling the MM5130, observe precautions as with any other ESD sensitive device. Do not exceed the voltage ratings specified in Table 1 below.
Table 1
Absolute

Maximum Ratings
1 Parameter Minimum Maximum Unit CW Input Power @ 6 GHz
25 W
Peak Input Power @ 6 GHz
150 W
Open State Voltage Rating / Switch
+/-150 V
RF1-4 to RFC 2 Open State Voltage RF1-RF4, RFC to GND,
+/-150 V
GATE pin to GND Potential 2 DC Voltage RFGATE Pins to
+/-100 V
RF1-RF4, RFC, GND (2) DC Current Rating / Switch
500 mA
Hot Switching Current @ 0.5 V
10 mA
Operating Temperature Range
-40 +85 ºC
Storage Temperature Range
-65 +150 ºC

1 All parameters must be within recommended operating conditions. Maximum DC and RF power can only be applied during the on-state condition (cold-switched condition). 2 This also applies to ESD events. This is a Class 0 device. © 2020 Menlo Microsystems, Inc. | All Rights Reserved | www.menlomicro.com