Datasheet ALDP105 (Panasonic) - 7

FabricantePanasonic
DescripciónCompliant with IEC/EN60335-1, IEC/EN60079-15 1 Form A 5 A Slim power relays
Páginas / Página10 / 7 — GUIDELINES FOR POWER, HIGH-CAPACITY DC CUT OFF AND SAFETY RELAYS USAGE. …
Formato / tamaño de archivoPDF / 205 Kb
Idioma del documentoInglés

GUIDELINES FOR POWER, HIGH-CAPACITY DC CUT OFF AND SAFETY RELAYS USAGE.  . ■

GUIDELINES FOR POWER, HIGH-CAPACITY DC CUT OFF AND SAFETY RELAYS USAGE   ■

Línea de modelo para esta hoja de datos

Versión de texto del documento

GUIDELINES FOR POWER, HIGH-CAPACITY DC CUT OFF AND SAFETY RELAYS USAGE   ■ For cautions for use, please read " GUIDELINES FOR RELAY USAGE ".  https://industry.panasonic.com/global/en/products/control/relay/cautions̲use Precautions for Coil Input   ■ Long term current carrying   ■ Coil connection A circuit that will be carrying a current continuously for  When connecting coils of polarized relays, please check coil  long periods without relay switching operation. ( circuits  polarity ( +, − ) at the internal connection diagram  for emergency lamps, alarm devices and error inspection   ( Schematic ). If any wrong connection is made, it may  that, for example, revert only during malfunction and  cause  unexpected malfunction, like abnormal heat, fire and  output warnings with form B contacts ) Continuous, long- so on, and circuit do not work. Avoid impressing voltages to  term current to the coil will facilitate deterioration of coil  the set coil and reset coil at the same time. insulation and characteristics due to heating of the coil itself. For circuits such as these, please use a magnetic-hold type    ■ Maximum allowable voltage and temperature  latching relay. If you need to use a single stable relay, use  rise a sealed type relay that is not easily affected by ambient  Proper usage requires that the rated coil voltage be  conditions and make a failsafe circuit design that considers  impressed on the coil. Note, however, that if a voltage  the possibility of contact failure or disconnection. greater than or equal to the maximum continuous voltage  is impressed on the coil, the coil may burn or its layers short    ■ DC Coil operating power due to the temperature rise. Furthermore, do not exceed the  Steady state DC current should be applied to the coil. The  usable ambient temperature range listed in the catalog.  wave form should be rectangular. If it includes ripple, the  ripple factor should be less than 5 %.    ● Operate voltage change due to coil temperature rise However, please check with the actual circuit since the  In DC relays, after continuous passage of current in  electrical characteristics may vary. The rated coil voltage  the coil, if the current is turned OFF, then immediately  should be applied to the coil and the set/reset pulse time of  turned ON again, due to the temperature rise in the  latching type relay differs for each relays, please refer to the  coil, the operate voltage will become somewhat  relay's individual specifications. higher. Also, it will be the same as using it in a higher  temperature atmosphere. The resistance/temperature  relationship for copper wire is about 0.4 % for 1 ℃,  and with this ratio the coil resistance increases. That  is, in order to operate of the relay, it is necessary that  the voltage be higher than the operate voltage and the  operate voltage rises in accordance with the increase  in the resistance value. However, for some polarized  relays, this rate of change is considerably smaller.  Panasonic Industry Co., Ltd. Electromechanical Control Business Division industry.panasonic.com Panasonic Industry Co., Ltd. 2024 ASCTB412E 202408 ー 6 ー