Equivalent input noise - - 2 µVrms Current channel NI - - 20 µVrms Voltage channel
Power supply
Current consumption IA+ID 4 - mA Power consumption (VDD = 5 V) PC - 25 mW Low voltage threshold for power failure PMLO - 4 - V detection High voltage threshold for power failure PMHI - 4.3 - V detection Built-in reference voltage
Typical Parameter Sign Minima Maxima Unit value
Reference voltage VREF +2.3 +2.43 +2.55 V Temperature drift TCVREF - 25 - ppm/℃ Numerical properties Unless otherwise specified, VDD = 5.0V, GND = 0V, on-chip reference voltage, on-chip oscillator, TMIN to TMAX = - 40℃ to 85℃
Typical Maxim Parameter Sign Minima Unit value a Master clock
Master clock frequency MCLK 3.04 3.579 4.12 MHz Duty ratio of master clock 30 50 70 %
Filter
Input sampling rate(DCLK = MCLK/K) - MCLK/4 - Hz Output code rate of digital filter MCLK/ OWR - - Hz 128 Turnover (- 3dB) frequency of high pass - 0.543 - Hz filter