MLX90392 3D Magnetometer 6.Conditions and Specifications6.1. Absolute Maximum Ratings (AMR) Operating Characteristics, TA = -40°C to 85°C (unless otherwise specified) ParameterSymbolMin.Typ.Max.UnitConditions Supply Voltage VS 2.3 V <48h Reverse voltage protection VSREV -0.3 V Room temp, <48h Output voltage VSDA, VSCL 2.3 V <48h Reverse output voltage VSDAREV -0.3 V Reverse clock output voltage VSCLREV -0.3 V ESD HBM (all pins) kV Operating Temperature TA -40 +85 °C Junction Temperature TJUNC +85 °C Storage Temperature Tstorage -40 150 °C Thermal resistance Rthja 230 K/W Junction to ambient 1s0p board 40 K/W Junction to ambient multi layered pcb Thermal resistance Rthjc 3.4 K/W Junction to case Magnetic Flux density -1 1 T Table 3– Absolute Maximum Ratings Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute maximum- rated conditions for extended periods may affect device reliability. 6.2. Operating Conditions6.2.1. General Operating ConditionsParameterSymbolMin.Typ.Max.UnitConditions Operating Temperature TA -40 +85 °C Storage Temperature Tstorage -40 150 °C Table 4 – General operating conditions 6.2.2. Electrical Operating ConditionsParameterSymbolMin.Typ.Max.UnitConditions Supply Voltage VS 1.65 1.8 1.95 V Table 5 – Electrical Operating conditions 6.2.3. Magnetic Operating ConditionsParameterSymbolMin.Typ.Max.UnitConditions Magnetic Flux density -5 5 mT version XXX-010 Magnetic Flux density -50 50 mT version XXX-011 Table 6 – Magnetic Operating conditions Revision 002 – 15 Apr 2021 Datasheet Page 7 of 40 3901090392