Datasheet MLX90392 (Melexis) - 7

FabricanteMelexis
Descripción3D Magnetometer
Páginas / Página40 / 7 — MLX90392. Conditions and Specifications. 6.1. Absolute Maximum Ratings …
Formato / tamaño de archivoPDF / 2.8 Mb
Idioma del documentoInglés

MLX90392. Conditions and Specifications. 6.1. Absolute Maximum Ratings (AMR). Parameter. Symbol. Min. Typ. Max. Unit. Conditions

MLX90392 Conditions and Specifications 6.1 Absolute Maximum Ratings (AMR) Parameter Symbol Min Typ Max Unit Conditions

Línea de modelo para esta hoja de datos

Versión de texto del documento

MLX90392
3D Magnetometer
6. Conditions and Specifications 6.1. Absolute Maximum Ratings (AMR)
Operating Characteristics, TA = -40°C to 85°C (unless otherwise specified)
Parameter Symbol Min. Typ. Max. Unit Conditions
Supply Voltage VS 2.3 V <48h Reverse voltage protection VSREV -0.3 V Room temp, <48h Output voltage VSDA, VSCL 2.3 V <48h Reverse output voltage VSDAREV -0.3 V Reverse clock output voltage VSCLREV -0.3 V ESD HBM (all pins) kV Operating Temperature TA -40 +85 °C Junction Temperature TJUNC +85 °C Storage Temperature Tstorage -40 150 °C Thermal resistance Rthja 230 K/W Junction to ambient 1s0p board 40 K/W Junction to ambient multi layered pcb Thermal resistance Rthjc 3.4 K/W Junction to case Magnetic Flux density -1 1 T Table 3– Absolute Maximum Ratings Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute maximum- rated conditions for extended periods may affect device reliability.
6.2. Operating Conditions 6.2.1. General Operating Conditions Parameter Symbol Min. Typ. Max. Unit Conditions
Operating Temperature TA -40 +85 °C Storage Temperature Tstorage -40 150 °C Table 4 – General operating conditions
6.2.2. Electrical Operating Conditions Parameter Symbol Min. Typ. Max. Unit Conditions
Supply Voltage VS 1.65 1.8 1.95 V Table 5 – Electrical Operating conditions
6.2.3. Magnetic Operating Conditions Parameter Symbol Min. Typ. Max. Unit Conditions
Magnetic Flux density -5 5 mT version XXX-010 Magnetic Flux density -50 50 mT version XXX-011 Table 6 – Magnetic Operating conditions Revision 002 – 15 Apr 2021 Datasheet Page 7 of 40 3901090392